Specifications
A low range ac
voltmeter offering a performance close to that of a full specification
vu meter , and suitable for connecting across a 600 ohm line and self
contained except for requiring an external 3.6k ohm resistor.
Calibrated for use with a 3.6k ohm resistor 4vu above the scale marking
so that the reference deflection (0vu) is produced by a signal 4vu above
1 m W in 600 ohms (1.228V). The performance of the meter is based
upon the requirements of BS 6840: Part 17:1991,IEC 268 – 17 1990. The
dynamic characteristics quoted, which requires the response time to 99%
of reference deflection (0vu) to be 0.3 seconds +/- 100% with an
overswing of at least 1.0% but not more than 1.5% are not fully met. The
overswing, because damping is not so tightly controlled but allowed to
spread within normal design restraints, can vary between deadbeat to 5%.
To specify the dynamic characteristics in terms of time to 99% of 0vu
under such circumstances would
give an
unrepresentative, measure of the speed of response. For this reason the
time to reach –3vu with a steady reading of reference deflection (0vu)
has been taken as a more realistic measure
The following comparison can
be made based on a rise time to –3vu with steady deflection of 0vu:
IEC............................................0.13
– 0.15 Seconds
AL19
Retro..................................0.14 - 0.18 Seconds
Features and
Benefits
-
Front of
panel mounting with full bezel
-
Constructed
with transparent acrylic front and high impact rear body molding.
Bezel molded in black ABS.
-
Taut band
core magnet movement Incorporated as standard. This rugged movement
makes these meters equally suitable for portable or fixed audio
applications. There is no calibration effect when mounted on a
ferrous panel.
Pointers and dials
The combination
of ‘pear’ shaped pointer and conventional arc scale on metal buff
colored dial results in an easily read meter, even when monitoring a row
on a large console. A white dial can be specified if required. The
standard scale is based on the vu ‘A’ scale as illustrated in the above
photograph but the ‘B’ scale with the ‘percent’ reading at the top can
be supplied to order at no extra cost.
Zero adjuster
Positioned on the rear as standard.
Certified drawings
Available on request.
Operating temperature
-25C to +55C
Illumination
Internal LED
illumination 12 Volt.
Terminals
Flying leads 125mm/5” long are standard, but 6mm tabs are available.
Dimensions

|